Flow Cell

Working Electrodes for Flow Cell

Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allow researchers to utilize them regardless the content of mobile phase of LC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes.

Features

  • Become Stable Immediately
  • Usable with Acid, Alkaline, and Organic Solvent
  • Easy Maintenance of Working Electrode by Wipe with Acetone
  • Working Electrodes can be Refreshed by using PK-2 Cell Polishing Kit
  • Can be used as Chemically derivatised Electrode or Bio-Sensor


     

Cross Flow Cell - Structure

Cross Flow Cell is capable of quantitation at the level of 10-15 mol by the flow rate : 1 mL/min - 100 µL/min.

Click to detail Click to detail
Features

  • Detection Electrode for HPLC
  • Electrode for Flow Injection
  • Electrode for Bio-sensor development
     
Catalog No. Description Applicatoin
010229 Cross flow cell (Glassy Carbon) Working electrode:GC, Dia.3mm x 2(Dual type)
010428 Cross flow cell (Platinum) Working electrode:Pt, Dia.3mm x 2(Dual type)
010781 Cross flow cell (Gold) Working electrode:Au, Dia.3mm x 2(Dual type)
Contents
Item Material Quantity
Working Electrode for Cross flow cell   1
Reference Electrode (RE-3V Silver-silver chloride Reference electrode Screw type) POM *1 1
Cross Flow cell block PEEK *2 1
Flow cell base block POM 1
Screw for base block SUS *3 2
Flow cell arm SUS 2
Screw for arm SUS 2
Working Electrode connector brass 1
Hand screw for clamp SUS 1
Stainless plate for clamp SUS 1
Clamped plate SUS 1
Teflon tubing ETFE 30cm
80cm
Silicone tubing Si 2cm
28cm
Stainless pipe 5cm SUS 1
TG-5M Teflon Gasket (Cross Flow) FEP 1
Dynaseal PEEK fingertight PEEK 3
*1 Polyacetal resin *2 Polyether-ether-ketone *3 Stainless Used Steel

 

Cross Flow Cell - Working Electrode


 

Radial Flow Cell

Radial Flow Cell is despeciallt developed for microbore chromatography. Its detecting efficiency will improve when flow rate is 10µL/min or lower. This flow cell consists of thin layer electrode and symmetric design.

 

Click to detail Click to detail


 

Catalog No. Description Applicatoin
010429 Radial flow cell (Glassy Carbon) Working electrode:GC, Dia.6mm(Single type)
010444 Radial flow cell (Platinum) Working electrode:Pt, Dia.3mm(Single type)
011237 Radial flow cell (Gold) Working electrode:Au, Dia.3mm(Single type)


 

Contents
Item Material Quantity
Working Electrode for Radial flow cell   1
Reference Electrode (RE-3V Silver-silver chloride Reference electrode Screw type) POM 1
Radial Flow cell block PEEK 1
Flow cell base block POM 1
Screw for base block SUS 2
Flow cell arm SUS 2
Screw for arm SUS 2
Hand screw for clamp SUS 1
Stainless plate for clamp SUS 1
Clamped plate SUS 1
Teflon tubing ETFE 30cm
80cm
Silicone tubing Si 2cm
28cm
Stainless pipe 5cm SUS 1
TG-5MR Teflon Gasket (Radial Flow) FEP 1
Dynaseal PEEK fingertight PEEK 3


 

Electrodes and Accessories for Flow Cell Kit

Application of Electorodes

  • GC: commonly used for measurement of Redox behaviour
  • PFC: commonly used for measurement of Redox behaviour
  • Au: measurement of thiol-related compounds with amalgamate electrode
  • Pt: measurement of hydrogen peroxide and oxidized substance
  • Ag: measurement of cyano-sulfide
  • CP: derivatizationed electrode by filling compound of carbon paste, enzyme and chemical substance into it
  • Ni: amino acid measurement by chemical derivatisation
Type Catalog No. Item Description
Cross
Flow
010300 Glassy Carbon Electrode for Cross flow cell Dia.3mm x 2(Dual Type),
Size: 25x25mm
010305 Gold Electrode for Cross flow cell
010328 Platinum Electrode for Cross flow cell
010325 Silver Electrode for Cross flow cell
010323 Carbon Paste Electrode for Cross flow cell
010326 Nickel Electrode for Cross flow cell
010337 TG-2M Teflon Gasket (4pcs) Film thickness: 12µm
010276 TG-5M Teflon Gasket (4pcs) Film thickness: 25µm
010338 TG-6M Teflon Gasket (4pcs) Film thickness: 50µm
010313 TG-8M Teflon Gasket (4pcs) Film thickness: 125µm
010349 TG-11M Silicon Gasket (4pcs) Film thickness: 500µm
010350 TG-12M Silicon Gasket (4pcs) Film thickness: 1000µm
010332 Cross Flow cell block Material: PEEK
Radial
Flow
010329 Glassy Carbon electrode for Radial flow cell Dia.6mm(Single Type),
Size: 25x25mm
010941 Copper electrode for Radial flow cell
010436 Platinum electrode for Radial flow cell Dia.3mm(Single Type),
Size: 25x25mm
011238 Gold Electrode for Radial flow cell
010322 PFCE Carbon electrode for Radial flow cell
011035 Carbon Paste Electrode for Radial flow cell
010630 TG-2MR Teflon Gasket (4pcs) Film thickness: 12µm
010353 TG-5MR Teflon Gasket (4pcs) Film thickness: 25µm
011925 TG-6MR Teflon Gasket (4pcs) Film thickness: 50µm
010331 Radial Flow cell block Material: PEEK
Cross/Radial 010298 RE-3V Ag/AgCl Reference electrode Screw type Size: Dia.10x48mm
010366 1/16" PEEK tubing ID:0.25mm, Length:3.0m
010430 Dynaseal PEEK fingertight(10pcs) Screw for pipe connecting
integrated 1/16"

<<Home                                                                    ALS Main Page